Home > ǰҰ > ޴



  
MultiRAE
հ

׸
VOC(ֹ߼ ȭչ), (Combustible, NDIR)
ϸϾ(NH3), ϻȭź(CO), ̻ȭź(CO2)
̻ȭ(CLO2), (CL2), (H2)
þȭ(HCN), Ȳȭ(H2s)
̻ȭ(NO2), (O2), (PH3)
̻ȭȲ(SO2), ƿ̵(ETO)
ƿĸź(CH3-SH)
ϻȭ(NO), ˵(HCHO)

ִ 6 ɡ VOC, CO2 30 پ
̸ ԰ ޴ϱ
18 پ ( ѱ )
̽ ä , Խ( IP65 )   Ȯ ( IP67 ) 
Ȯ ( diffusion ) Խ ( pumped ) Ÿ  
پ ( ƿİź , ƿ̵ , ˵ )  
dz VOC HCHO ( MultiRAE PRO Ÿ ý )
( MultiRAE PRO Ÿ ý )
ݴ
LCD ȭ ڰ бⰡ
ð ִ Ƭ ͸ ž / ī 嵥 ȣȯ
Visual, Sound, Vibration 3 溸 ۵
RFI
Data
۽ (ɼ)
Ÿ 200 m


ѱ 븮 ż A/S κ



Model

MultiRAE Pro

MultiRAE

MultiRAE Lite

ܰ

Gamma Radidation Sensor

O

X

X

Ppb PID
(10.6 eV: 0.01~2000ppm : 10ppb res)

O

X

X

High-Range Ppm PID
(10.6 eV: 1~1000ppm : 1ppm res)

O

O

O
(Pumped only)

ETO-C Extended range, H2

X

X

O
(Diffusion only)

20+ Electrochemical sensor

O

O

O

H2S , HR extended range sensor

X

X

O
(Diffusion only)

Catalytic %LEL Sensor

O

O

O

CombustibleNDIR Sensors
(%LEL or %Vol.CH4)

O

O

O
(Pumped only)

CO2 NDIR Sensor

O

O

O

Sampling

Pumped

Pumped

Pumped or Diffusion

Model

MultiRAE

Sensor

PID Sensor

Range(ppm)

Resolution(ppm)

VOC 10.6 eV (HR)

0 to 5,000 ppm

0.1 ppm

VOC 10.6 eV (ppb)

0 to 2,000 ppm

0.01ppm

VOC 10.6 eV

0 to 1,000 ppm

0.1 ppm

Catalytic LEL

0 to 100% LEL

1% LEL

NDIR(0-100% LEL Methane)

0 to 100% LEL

1% LEL

NDIR(0-100% Vol. Methane)

0 to 100% Vol.

0.1% Vol.

Carbon Dioxide Sensor

Range(ppm)

Resolution(ppm)

Carbon Dioxide(CO2) NDIR

0 to 50,000 ppm

100 ppm

Electrochemical Sensors

Range(ppm)

Resolution(ppm)

Ammonia (NH3)

0 to 100 ppm

1 ppm

Carbon Monoxide (CO)

0 to 500 ppm

1 ppm

Carbon Monoxide (CO), Ext.Range

0 to 2,000 ppm

10 ppm

Carbon Monoxide (CO), H2-comp

0 to 2,000 ppm

10 ppm

Carbon Monoxide (CO) +
Hydrogen Sulfide (H2S) Combo

0 to 500 ppm
0 to 200 ppm

1 ppm
0.1 ppm

Chlorine(cl2)

0 to 50 ppm

0.1 ppm

Chlorine Dioxide(ClO2)

0 to 1 ppm

0.03 ppm

Ethylene Oxide(EtO-A)

0 to 100 ppm

0.5 ppm

Ethylene Oxide(EtO-B)

0 to 10 ppm

0.1 ppm

Ethylene Oxide(EtO-C), Ext.Range

0 to 500 ppm

10 ppm

Formaldehyde (HCHO)

0 to 10 ppm

0.01 ppm

Hydrogen (H2)

0 to 1,000 ppm

2 ppm

Hydrogen Chloride (HCN)

0 to 50 ppm

0.5 ppm

Hydrogen Sulfide (H2S)

0 to 100 ppm

0.1 ppm

Hydrogen Sulfide (H2S), Ext.Range

0 to 1,000 ppm

1 ppm

Methyl Mercaptan (CH3-SH)

0 to 10 ppm

0.1 ppm

Nitric Oxide (NO)

0 to 250 ppm

0.5 ppm

Nitrogen Dioxide (NO2)

0 to 20 ppm

0.1 ppm

Oxygen (O2)

0 to 30% Vol

0.1% Vol.

Phosphine (PH3)

0 to 20 ppm

0.1 ppm

Phosphine (PH3), Ext.Range

0 to 1,000 ppm

1 ppm

Sulfur Dioxide (SO2)

0 to 20 ppm

0.1 ppm

Size

193 mm x 96.5 mm x 66 mm

Weight

880 g with clip

Battery

Recharrgeable Lithium-ion battery (12ð ӻ)

Wireless Network

RAE Systems Dedicated Wireless Network

Datalogging

Continuous datalogging with a 3 month capacity

Sampling

Built in pump or Diffusion

Calibration

Two point field calibration: auto-zero at startup, user intiated span / standard reference gas

Hazardous Area Approval

UL/CL Classified for use in Class 1, Division II, Groups A,B,C, and D.
Class 2 Groups E, F, G Hazardous Locations, Temp Code T3C

Warranty

2 years for instrument and CO, O2 and H2s sensors
(All other sensors have 1-year warranty)