Home > ǰҰ > ޴



  
UNI SERIES
ϰ

• ԰ : 88 X 62 X 33 mm , ߷ : 125 g

• : Class I, Div 1, Group A, B, C, D; Class II, Div 1, Group E, F, G; Class III, Div 1

• µ : T4, -20 C Tamb +50 C

̺Ʈ ΰ

: IP – 67

LCD ȭ ž

ȣԷ

1 2

6 LED ž

, ϻȭ ź , Ȳȭ ž

17 ׸ ð

                


           

Model UNI SERIES
Size (88 x 62 x 33 mm)
Weight (125 g)
Temperature -4 to 122 (-20 to 50)
Humidity 5 to 95% relative humidity   (non-condensing)
Alarm type High alarm, Low alarm, STEL   alarm, TWA alarm, adjustable.
Over-range alarm, Battery low alarm.
Alarm signal 90dB @ 30cm audible
Bright red LED
Built in vibrator
Calibration 2-point calibration, zero and   span, power
on zero (user-selectable)
Event log Up to 10 alarm events
Response time (t90) 20 seconds (CO/H2S/O2), Others vary, see individual sensor   specification sheet
IP rating IP-67
EMI/RFI Compliant with EMC 2004/108/EC
Safety certifications UL/cUL:
Class I, Div 1, Groups A, B, C, D
Class II, Div 1, Groups E, F, G
Class III, Div 1
T4, -20 C Tamb +50 C
Battery Replaceable AA size Lithium battery, 3 years typical operation
Sensor life CO/H2S expected operating life 5 years or longer, others 2   years or longer

      
Gas Measuring Range
/Resolution (ppm)
CO 500/1
1000/1
2000/1
H2S 50.0/0.1
100.0/0.1
200.0/0.1
1000/1
O2 25.0/0.1%
30/0.1%
H2 1000/1
2000/1
NH3 50/1
Cl2 10.0/0.1
ClO2 1.00/0.01
HCN 100/1
NO 250/1
NO2 20.0/0.1
PH3 20.0/0.01
SO2 20.0/0.1
ETO 100.0/0.1
200.0/0.1
O3 1.00/0.02
HF 10.0/0.1
HCl 15.0/0.1
CH3SH 10.0/0.1
C2H4O 20.0/0.1